SIP User's Manual 46 Document #: LTRT-65412
MP-11x & MP-124
3. Click the Get Scenario File button; the 'File Download' window appears.
4. Click Save, and then in the 'Save As' window navigate to the folder to where you want
to save the Scenario file. When the file is successfully downloaded to your PC, the
'Download Complete' window appears.
5. Click Close to close the 'Download Complete' window.
3.1.7.5 Loading a Scenario to the Device
Instead of creating a Scenario, you can load a Scenario file (data file) from your PC to the
device.
¾ To load a Scenario to the device:
1. On the Navigation bar, click the Scenarios tab; the Scenario appears in the Navigation
tree.
2. Click the Get/Send Scenario File button (located at the bottom of the Navigation tree);
the 'Scenario File' page appears (refer to ''Saving a Scenario to a PC'' on page 45).
3. Click the Browse button, and then navigate to the Scenario file stored on your PC.
4. Click the Send File button.
Notes:
You can only load a Scenario file to a device that has an identical
hardware configuration setup to the device in which it was created. For
example, if the Scenario was created in a device with FXS interfaces, the
Scenario cannot be loaded to a device that does not have FXS
interfaces.
The loaded Scenario replaces any existing Scenario.
You can also load a Scenario file using BootP, by loading an ini file that
contains the ini file parameter ScenarioFileName (refer to ''Web and
Telnet Parameters'' on page 229). The Scenario dat file must be located
in the same folder as the ini file. For a detailed description on BootP, refer
to the Product Reference Manual.

Table of Contents

Other manuals for AudioCodes MP-124

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes MP-124 and is the answer not in the manual?

AudioCodes MP-124 Specifications

General IconGeneral
ModelMP-124
CategoryGateway
Analog Ports24 FXS
Ethernet Ports2
Protocol SupportSIP, H.323
Fax SupportT.38, G.711 pass-through
Power Supply100-240VAC, 50-60Hz
Operating Temperature0°C to 40°C
Voice CodecsG.711, G.729, G.723.1, G.726
ManagementSNMP
Storage Temperature-20°C to 70°C
Humidity10% to 90%, non-condensing
Network Interface10/100Base-T Ethernet

Related product manuals