6.2.2 Web Parameters
The Web parameters are described in the table below.
Table 6-12: Web Parameters
Parameter Description
[DisableWebTask]
Disables or enables device management through the Web interface.
[0] = Enable Web management (default).
[1] = Disable Web management.
Note: For this parameter to take effect, a device reset is required.
[HTTPport]
HTTP port used for Web management (default is 80).
Note: For this parameter to take effect, a device reset is required.
EMS: Disable WEB
Config
[DisableWebConfig]
Determines whether the entire Web interface is in read-only mode.
[0] = Enables modifications of parameters (default).
[1] = Web interface in read-only mode.
When in read-only mode, parameters can't be modified. In addition, the
following pages can't be accessed: 'Web User Accounts', 'Certificates',
'Regional Settings', 'Maintenance Actions' and all file-loading pages
('Load Auxiliary Files', 'Software Upgrade Wizard', and 'Configuration
File').
Notes:
For this parameter to take effect, a device reset is required.
To return to read/write after you have applied read-only using this
parameter (set to 1), you need to reboot your device with an ini file
that doesn't include this parameter, using the BootP/TFTP Server
utility (refer to the Product Reference Manual).
[ResetWebPassword]
Resets the username and password of the primary and secondary
accounts to their defaults.
[0] = Password and username retain their values (default).
[1] = Password and username are reset (for the default username
and password, refer to User Accounts).
Notes:
For this parameter to take effect, a device reset is required.
The username and password cannot be reset from the Web interface
(i.e., via AdminPage or by loading an ini file).
[ScenarioFileName]
Defines the file name of the Scenario file to be loaded to the device. The
file name must have the dat extension and can be up to 47 characters.
For loading a Scenario using the Web interface, refer to Loading a
Scenario to the Device on page 46.

Table of Contents

Other manuals for AudioCodes MP-124

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes MP-124 and is the answer not in the manual?

AudioCodes MP-124 Specifications

General IconGeneral
ModelMP-124
CategoryGateway
Analog Ports24 FXS
Ethernet Ports2
Protocol SupportSIP, H.323
Fax SupportT.38, G.711 pass-through
Power Supply100-240VAC, 50-60Hz
Operating Temperature0°C to 40°C
Voice CodecsG.711, G.729, G.723.1, G.726
ManagementSNMP
Storage Temperature-20°C to 70°C
Humidity10% to 90%, non-condensing
Network Interface10/100Base-T Ethernet