Version 5.8 43 September 2009
SIP User's Manual 3. Web-Based Management
3.1.7.2 Accessing a Scenario
Once you have created the Scenario, you can access it at anytime by following the
procedure below:
¾ To access the Scenario:
1. On the Navigation bar, select the Scenario tab; a message box appears, requesting
you to confirm the loading of the Scenario.
Figure 3-16: Scenario Loading Message Box
2. Click OK; the Scenario and its Steps appear in the Navigation tree, as shown in the
example figure below:
Figure 3-17: Scenario Example
When you select a Scenario Step, the corresponding page is displayed in the Work pane. In
each page, the available parameters are indicated by a dark-blue background; the
unavailable parameters are indicated by a gray or light-blue background.

Table of Contents

Other manuals for AudioCodes MP-124

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes MP-124 and is the answer not in the manual?

AudioCodes MP-124 Specifications

General IconGeneral
ModelMP-124
CategoryGateway
Analog Ports24 FXS
Ethernet Ports2
Protocol SupportSIP, H.323
Fax SupportT.38, G.711 pass-through
Power Supply100-240VAC, 50-60Hz
Operating Temperature0°C to 40°C
Voice CodecsG.711, G.729, G.723.1, G.726
ManagementSNMP
Storage Temperature-20°C to 70°C
Humidity10% to 90%, non-condensing
Network Interface10/100Base-T Ethernet