EasyManua.ls Logo

AudioCodes MP-124 - NTP and Daylight Saving Time Parameters; Table 6-9: NTP and Daylight Saving Time Parameters

AudioCodes MP-124
486 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Version 5.8 227 September 2009
SIP User's Manual 6. Configuration Parameters Reference
Parameter Description
lease.
Note: For this parameter to take effect, a device reset is required.
6.1.9 NTP and Daylight Saving Time Parameters
The Network Time Protocol (NTP) and daylight saving time parameters are described in the
table below.
Table 6-9: NTP and Daylight Saving Time Parameters
Parameter Description
NTP Parameters
Note: For detailed information on Network Time Protocol (NTP), refer to ''Simple Network Time
Protocol Support'' on page 453.
Web: NTP Server IP Address
EMS: Server IP Address
[NTPServerIP]
The IP address (in dotted-decimal notation) of the NTP server.
The default IP address is 0.0.0.0 (i.e., internal NTP client is
disabled).
Web: NTP UTC Offset
EMS: UTC Offset
[NTPServerUTCOffset]
Defines the Universal Time Coordinate (UTC) offset (in seconds)
from the NTP server.
The default offset is 0. The offset range is -43200 to 43200.
Web: NTP Update Interval
EMS: Update Interval
[NTPUpdateInterval]
Defines the time interval (in seconds) that the NTP client requests
for a time update.
The default interval is 86400 (i.e., 24 hours). The range is 0 to
214783647.
Note: It is not recommend to set this parameter to beyond one
month (i.e., 2592000 seconds).
Daylight Saving Time Parameters
Day Light Saving Time
[DayLightSavingTimeEnable]
Determines whether to enable daylight saving time.
[0] Disable (default)
[1] Enable
Start Time
[DayLightSavingTimeStart]
Defines the date and time when daylight saving begins.
The format of the value is mo:dd:hh:mm (month, day, hour,
minutes).
End Time
[DayLightSavingTimeEnd]
Defines the date and time when daylight saving ends.
The format of the value is mo:dd:hh:mm (month, day, hour,
minutes).
Offset
[DayLightSavingTimeOffset]
Daylight saving time offset (in minutes).
The valid range is 0 to 120. The default is 60.