9.5.2.5 Fax / Modem Transparent with Events Mode
In this mode, fax and modem signals are transferred using the current voice coder with the
following automatic adaptations:
Echo Canceller = on (or off, for modems)
Echo Canceller Non-Linear Processor Mode = off
Jitter buffering optimizations
To configure fax / modem transparent with events mode, perform the following
configurations:
IsFaxUsed = 0
FaxTransportMode = 3
V21ModemTransportType = 3
V22ModemTransportType = 3
V23ModemTransportType = 3
V32ModemTransportType = 3
V34ModemTransportType = 3
BellModemTransportType = 3
9.5.2.6 G.711 Fax / Modem Transport Mode
In this mode, when the terminating device detects fax or modem signals (CED or AnsAM), it
sends a Re-INVITE message to the originating device requesting it to re-open the channel
in G.711 VBD with the following adaptations:
Echo Canceller = off
Silence Compression = off
Echo Canceller Non-Linear Processor Mode = off
Dynamic Jitter Buffer Minimum Delay = 40
Dynamic Jitter Buffer Optimization Factor = 13
After a few seconds upon detection of fax V.21 preamble or super G3 fax signals, the
device sends a second Re-INVITE enabling the echo canceller (the echo canceller is
disabled only on modem transmission).
A ‘gpmd’ attribute is added to the SDP according to the following format:
For G.711A-law: a=gpmd:0 vbd=yes;ecan=on (or off, for modems)
For G.711 µ-law: a=gpmd:8 vbd=yes;ecan=on (or off for modems)
The parameters FaxTransportMode and VxxModemTransportType are ignored and
automatically set to the mode called ‘transparent with events’.
To configure fax / modem transparent mode, set IsFaxUsed to 2.

Table of Contents

Other manuals for AudioCodes MP-124

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes MP-124 and is the answer not in the manual?

AudioCodes MP-124 Specifications

General IconGeneral
ModelMP-124
CategoryGateway
Analog Ports24 FXS
Ethernet Ports2
Protocol SupportSIP, H.323
Fax SupportT.38, G.711 pass-through
Power Supply100-240VAC, 50-60Hz
Operating Temperature0°C to 40°C
Voice CodecsG.711, G.729, G.723.1, G.726
ManagementSNMP
Storage Temperature-20°C to 70°C
Humidity10% to 90%, non-condensing
Network Interface10/100Base-T Ethernet

Related product manuals