SIP User's Manual 400 Document #: LTRT-65412
MP-11x & MP-124
V21ModemTransportType = 2
V22ModemTransportType = 2
V23ModemTransportType = 2
V32ModemTransportType = 2
V34ModemTransportType = 2
BellModemTransportType = 2
9.5.2.4 Fax / Modem Transparent Mode
In this mode, fax and modem signals are transferred using the current voice coder without
notifications to the user and without automatic adaptations. It's possible to use the Profiles
mechanism (refer to ''Coders and Profile Definitions'' on page 104) to ap
ply certain
adaptations to the channel used for fax / modem (e.g., to use the coder G.711, to set the
jitter buffer optimization factor to 13, and to enable echo cancellation for fax and disable it
for modem).
To configure fax / modem transparent mode, use the following parameters:
IsFaxUsed = 0
FaxTransportMode = 0
V21ModemTransportType = 0
V22ModemTransportType = 0
V23ModemTransportType = 0
V32ModemTransportType = 0
V34ModemTransportType = 0
BellModemTransportType = 0
Additional configuration parameters:
CoderName
DJBufOptFactor
EnableSilenceCompression
EnableEchoCanceller
Note: This mode can be used for fax, but is not recommended for modem
transmission. Instead, use the modes Bypass (refer to ''Fax/Modem Bypass
Mode'' on page 398) or Transparent with Events (refer to ''Fax / Modem
Transparent with Events Mode'' on page 400) for modem.

Table of Contents

Other manuals for AudioCodes MP-124

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes MP-124 and is the answer not in the manual?

AudioCodes MP-124 Specifications

General IconGeneral
ModelMP-124
CategoryGateway
Analog Ports24 FXS
Ethernet Ports2
Protocol SupportSIP, H.323
Fax SupportT.38, G.711 pass-through
Power Supply100-240VAC, 50-60Hz
Operating Temperature0°C to 40°C
Voice CodecsG.711, G.729, G.723.1, G.726
ManagementSNMP
Storage Temperature-20°C to 70°C
Humidity10% to 90%, non-condensing
Network Interface10/100Base-T Ethernet

Related product manuals