EasyManuals Logo

AudioCodes MP-124 User Manual

AudioCodes MP-124
486 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #250 background imageLoading...
Page #250 background image
SIP User's Manual 250 Document #: LTRT-65412
MP-11x & MP-124
6.6 SNMP Parameters
The SNMP parameters are described in the table below.
Table 6-28: SNMP Parameters
Parameter Description
Enable SNMP
[DisableSNMP]
Determines whether SNMP is enabled.
[0] Enable = SNMP is enabled (default).
[1] Disable = SNMP is disabled and no traps are sent.
[SNMPPort]
The device's local UDP port used for SNMP Get/Set
commands.
The range is 100 to 3999. The default port is 161.
Note: For this parameter to take effect, a device reset is
required.
[SNMPTrustedMGR_x]
Defines up to five IP addresses of remote trusted SNMP
managers from which the SNMP agent accepts and
processes SNMP Get and Set requests.
Notes:
By default, the SNMP agent accepts SNMP Get and
Set requests from any IP address, as long as the
correct community string is used in the request.
Security can be enhanced by using Trusted Managers,
which is an IP address from which the SNMP agent
accepts and processes SNMP requests.
If no values are assigned to these parameters any
manager can access the device.
Trusted managers can work with all community
strings.
EMS: Keep Alive Trap Port
[KeepAliveTrapPort]
The port to which the keep-alive traps are sent.
The valid range is 0 - 65534. The default is port 162.
[SendKeepAliveTrap]
When enabled, this parameter invokes the keep-alive trap
and sends it every 9/10 of the time defined in the
parameter defining NAT Binding Default Timeout.
[0] = Disable
[1] = Enable
Note: For this parameter to take effect, a device reset is
required.
[SNMPSysOid]
Defines the base product system OID.
The default is eSNMP_AC_PRODUCT_BASE_OID_D.
Note: For this parameter to take effect, a device reset is
required.
[SNMPTrapEnterpriseOid]
Defines a Trap Enterprise OID.
The default is eSNMP_AC_ENTERPRISE_OID.
The inner shift of the trap in the AcTrap subtree is added
to the end of the OID in this parameter.
Note: For this parameter to take effect, a device reset is
required.

Table of Contents

Other manuals for AudioCodes MP-124

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes MP-124 and is the answer not in the manual?

AudioCodes MP-124 Specifications

General IconGeneral
ModelMP-124
CategoryGateway
Analog Ports24 FXS
Ethernet Ports2
Protocol SupportSIP, H.323
Fax SupportT.38, G.711 pass-through
Power Supply100-240VAC, 50-60Hz
Operating Temperature0°C to 40°C
Voice CodecsG.711, G.729, G.723.1, G.726
ManagementSNMP
Storage Temperature-20°C to 70°C
Humidity10% to 90%, non-condensing
Network Interface10/100Base-T Ethernet

Related product manuals