Version 5.8 249 September 2009
SIP User's Manual 6. Configuration Parameters Reference
Parameter Description
RADIUS Authentication Server
IP Address
[RADIUSAuthServerIP]
IP address of the RADIUS authentication server.
Note: For this parameter to take effect, a device reset is required.
[RADIUSAuthPort]
RADIUS Authentication Server Port.
Note: For this parameter to take effect, a device reset is required.
RADIUS Shared Secret
[SharedSecret]
'Secret' used to authenticate the device to the RADIUS server.
This should be a cryptically strong password.
Default Access Level
[DefaultAccessLevel]
Defines the default access level for the device when the RADIUS
(authentication) response doesn't include an access level
attribute.
The valid range is 0 to 255. The default value is 200 (Security
Administrator').
Local RADIUS Password Cache
Mode
[RadiusLocalCacheMode]
Defines the device's mode of operation regarding the timer
(configured by the parameter RadiusLocalCacheTimeout) that
determines the validity of the user name and password (verified
by the RADIUS server).
[0] Absolute Expiry Timer = when you access a Web page, the
timeout doesn't reset, instead it continues decreasing.
[1] Reset Timer Upon Access = upon each access to a Web
page, the timeout always resets (reverts to the initial value
configured by RadiusLocalCacheTimeout).
Local RADIUS Password Cache
Timeout
[RadiusLocalCacheTimeout]
Defines the time (in seconds) the locally stored user name and
password (verified by the RADIUS server) are valid. When this
time expires, the user name and password become invalid and a
must be re-verified with the RADIUS server.
The valid range is 1 to 0xFFFFFF. The default value is 300 (5
minutes).
[-1] = Never expires.
[0] = Each request requires RADIUS authentication.
RADIUS VSA Vendor ID
[RadiusVSAVendorID]
Defines the vendor ID that the device accepts when parsing a
RADIUS response packet.
The valid range is 0 to 0xFFFFFFFF. The default value is 5003.
RADIUS VSA Access Level
Attribute
[RadiusVSAAccessAttribute]
Defines the code that indicates the access level attribute in the
Vendor Specific Attributes (VSA) section of the received RADIUS
packet.
The valid range is 0 to 255. The default value is 35.

Table of Contents

Other manuals for AudioCodes MP-124

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes MP-124 and is the answer not in the manual?

AudioCodes MP-124 Specifications

General IconGeneral
ModelMP-124
CategoryGateway
Analog Ports24 FXS
Ethernet Ports2
Protocol SupportSIP, H.323
Fax SupportT.38, G.711 pass-through
Power Supply100-240VAC, 50-60Hz
Operating Temperature0°C to 40°C
Voice CodecsG.711, G.729, G.723.1, G.726
ManagementSNMP
Storage Temperature-20°C to 70°C
Humidity10% to 90%, non-condensing
Network Interface10/100Base-T Ethernet