Version 5.8 239 September 2009
SIP User's Manual 6. Configuration Parameters Reference
Parameter Description
[BootPDelay]
The interval between the device's startup and the first BootP/DHCP
request that is issued by the device.
[1] = 1 second (default).
[2] = 3 second.
[3] = 6 second.
[4] = 30 second.
[5] = 60 second.
Note: For this parameter to take effect, a device reset is required.
[ExtBootPReqEnable]
[0] = Disable (default).
[1] = Enable extended information to be sent in BootP request.
If enabled, the device uses the vendor specific information field in the
BootP request to provide device-related initial startup information such
as blade type, current IP address, software version. For a full list of the
vendor specific Information fields, refer to the Product Reference
Manual.
The BootP/TFTP configuration utility displays this information in the
'Client Info' column.
Notes:
This option is not available on DHCP servers.
For this parameter to take effect, a device reset is required.

Table of Contents