EasyManuals Logo

AudioCodes MP-124 User Manual

AudioCodes MP-124
486 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #270 background imageLoading...
Page #270 background image
SIP User's Manual 270 Document #: LTRT-65412
MP-11x & MP-124
Parameter Description
IP Group Table
[IPGroup]
This ini file table parameter configures the IP Group table.
The format of this parameter is as follows:
[IPGroup]
FORMAT IPGroup_Index = IPGroup_Type,
IPGroup_Description, IPGroup_ProxySetId,
IPGroup_SIPGroupName, IPGroup_ContactUser,
IPGroup_EnableSurvivability, IPGroup_ServingIPGroup,
IPGroup_SipReRoutingMode,
IPGroup_AlwaysUseRouteTable,
IPGroup_RoutingMode, IPGroup_SRD,
IPGroup_MediaRealm, IPGroup_ClassifyByProxySet,
IPGroup_ProfileId;
[\IPGroup]
For example:
IPGroup 1 = 0, "dol gateway", 1, firstIPgroup, , 0, -1, 0, 0, -
1, 0, , 1, 1;
IPGroup 2 = 0, "abc server", 2, secondIPgroup, , 0, -1, 0, 0,
-1, 0, , 1, 2;
IPGroup 3 = 1, "IP phones", 1, thirdIPGroup, , 0, -1, 0, 0, -1,
0, , 1, 2;
Notes:
This table parameter can include up to 9 indices (1-9).
The parameters IPGroup_Type,
IPGroup_EnableSurvivability, IPGroup_ServingIPGroup,
IPGroup_RoutingMode, IPGroup_SRD,
IPGroup_MediaRealm, and
IPGroup_ClassifyByProxySet are currently not
applicable and must be left empty (or -1).
For a detailed description of the ini file table's
parameters and for configuring this table using the Web
interface, refer to ''Configuring the IP Groups'' on page
99.
For an explanation on using ini file table parameters,
refer to ''Format of ini File Table Parameters'' on page
191.

Table of Contents

Other manuals for AudioCodes MP-124

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes MP-124 and is the answer not in the manual?

AudioCodes MP-124 Specifications

General IconGeneral
ModelMP-124
CategoryGateway
Analog Ports24 FXS
Ethernet Ports2
Protocol SupportSIP, H.323
Fax SupportT.38, G.711 pass-through
Power Supply100-240VAC, 50-60Hz
Operating Temperature0°C to 40°C
Voice CodecsG.711, G.729, G.723.1, G.726
ManagementSNMP
Storage Temperature-20°C to 70°C
Humidity10% to 90%, non-condensing
Network Interface10/100Base-T Ethernet

Related product manuals