EasyManuals Logo

AudioCodes MP-124 User Manual

AudioCodes MP-124
486 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #297 background imageLoading...
Page #297 background image
Version 5.8 297 September 2009
SIP User's Manual 6. Configuration Parameters Reference
Parameter Description
Web/EMS: MWI Server Transport
Type
[MWIServerTransportType]
Determines the transport layer used for outgoing SIP dialogs
initiated by the device to the MWI Server.
[-1] Not Configured (default)
[0] UDP
[1] TCP
[2] TLS
Note: When set to ‘Not Configured’, the value of the parameter
SIPTransportType is used.
Web: MWI Subscribe Expiration
Time
EMS: MWI Expiration Time
[MWIExpirationTime]
The MWI subscription expiration time in seconds.
The default is 7200 seconds. The range is 10 to 72000.
Web: MWI Subscribe Retry Time
EMS: Subscribe Retry Time
[SubscribeRetryTime]
Subscription retry time (in seconds) after last subscription
failure.
The default is 120 seconds. The range is 10 to 7200.
Subscription Mode
[SubscriptionMode]
Determines the method the device uses to subscribe to an
MWI server.
[0] Per Endpoint = Each endpoint subscribes separately -
typically used for FXS interfaces (default).
[1] Per Gateway = Single subscription for the entire device -
typically used for FXO interfaces.
[ETSIVMWITypeOneStandard]
Selects the ETSI Visual Message Waiting Indication (VMWI)
Type 1 sub-standard.
[0] = ETSI VMWI between rings (default)
[1] = ETSI VMWI before ring DT_AS
[2] = ETSI VMWI before ring RP_AS
[3] = ETSI VMWI before ring LR_DT_AS
[4] = ETSI VMWI not ring related DT_AS
[5] = ETSI VMWI not ring related RP_AS
[6] = ETSI VMWI not ring related LR_DT_AS
Note: For this parameter to take effect, a device reset is
required.
[BellcoreVMWITypeOneStandard]
Selects the Bellcore VMWI sub-standard.
[0] = Between rings (default).
[1] = Not ring related.
Note: For this parameter to take effect, a device reset is
required.

Table of Contents

Other manuals for AudioCodes MP-124

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes MP-124 and is the answer not in the manual?

AudioCodes MP-124 Specifications

General IconGeneral
ModelMP-124
CategoryGateway
Analog Ports24 FXS
Ethernet Ports2
Protocol SupportSIP, H.323
Fax SupportT.38, G.711 pass-through
Power Supply100-240VAC, 50-60Hz
Operating Temperature0°C to 40°C
Voice CodecsG.711, G.729, G.723.1, G.726
ManagementSNMP
Storage Temperature-20°C to 70°C
Humidity10% to 90%, non-condensing
Network Interface10/100Base-T Ethernet

Related product manuals