Version 5.8 301 September 2009
SIP User's Manual 6. Configuration Parameters Reference
Parameter Description
Max 3 Way Conference On Board
Calls
[MaxInBoardConferenceCalls]
Determines the maximum number of simultaneous, on-board
three-way conference calls.
The valid range is 0 to 2. The default is 2.
Notes:
For enabling on-board, three-way conferencing, use the
parameter 3WayConferenceMode.
This parameter is applicable only to FXS interfaces.
Three Way Conference Non
Allocatable Ports
[3WayConfNoneAllocateablePorts]
Determines the ports that are not allocated as resources for
on-board three-way conference calls that are initiated by
other ports. Ports that are not configured with this parameter
(and that are idle) are used by the device as a resource for
establishing these type of conference calls.
The valid range is up to 8 ports. To add a range of ports, use
the comma separator. For example, for not allowing the use
of ports 2, 4 and 8 as resources, enter the following value:
2,4,8. The order of the entered values is not relevant (i.e., the
example above can be entered as 8,2,4). The default is 0.
Notes:
To enable on-board, three-way conferencing, use the
parameters 3WayConferenceMode and
MaxInBoardConferenceCalls.
This parameter is applicable only to FXS interfaces.
Establish Conference Code
[ConferenceCode]
Defines the digit pattern, which upon detection, generates the
Conference-initiating INVITE when 3-way conferencing is
enabled (Enable3WayConference is set to 1).
The valid range is a 25-character string. The default is “!”
(Hook-Flash).
Conference ID
[ConferenceID]
Defines the Conference Identification string (up to 16
characters). The default value is 'conf'.
The device uses this identifier in the Conference-initiating
INVITE that is sent to the media server when
Enable3WayConference is set to 1.
For example: ConferenceID = MyConference.