SIP User's Manual 360 Document #: LTRT-65412
MP-11x & MP-124
Parameter Description
Web: Max Digits in Phone
Num
EMS: Max Digits in Phone
Number
[MaxDigits]
Defines the maximum number of collected destination number
digits that can be received (i.e., dialed) from the Tel side . When the
number of collected digits reaches the maximum, the device uses
these digits for the called destination number.
The valid range is 1 to 49. The default value is 5.
Notes:
Digit Mapping Rules can be used instead.
Dialing ends when any of the following scenarios occur:
9 Maximum number of digits is dialed
9 Interdigit Timeout (TimeBetweenDigits) expires
9 Pound (#) key is pressed
9 Digit map pattern is matched
Web: Inter Digit Timeout for
Overlap Dialing [sec]
EMS: Interdigit Timeout (Sec)
[TimeBetweenDigits]
Defines the time (in seconds) that the device waits between digits
that are dialed by the calling party for Tel-to-IP calls. When this
inter-digit timeout expires, the device uses the collected digits to
dial the called destination number.
The valid range is 1 to 10. The default value is 4.

Table of Contents

Other manuals for AudioCodes MP-124

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes MP-124 and is the answer not in the manual?

AudioCodes MP-124 Specifications

General IconGeneral
ModelMP-124
CategoryGateway
Analog Ports24 FXS
Ethernet Ports2
Protocol SupportSIP, H.323
Fax SupportT.38, G.711 pass-through
Power Supply100-240VAC, 50-60Hz
Operating Temperature0°C to 40°C
Voice CodecsG.711, G.729, G.723.1, G.726
ManagementSNMP
Storage Temperature-20°C to 70°C
Humidity10% to 90%, non-condensing
Network Interface10/100Base-T Ethernet

Related product manuals