Version 5.8 447 September 2009
SIP User's Manual 9. IP Telephony Capabilities
Figure 9-27: Configuring Endpoints
2. In the ‘Automatic Dialing’ page (refer to ''Automatic Dialing'' on page 143), e
nter the
phone numbers of the FXO device in the ‘Destination Phone Number’ fields. When a
phone connected to Port #1 off-hooks, the FXS device automatically dials the number
‘200’.
Figure 9-28: Configuring Automatic Dialing
3. In the ‘Tel to IP Routing’ page (refer to ''Tel to IP Routing Table'' on page 131), enter
20 for the destinatio
n phone prefix, and 10.1.10.2 for the IP address of the FXO
device.
Figure 9-29: Configuring Tel to IP Routing
Note: For the transfer to function in remote PBX extensions, Hold must be disabled
at the FXS device (i.e., Enable Hold = 0) and hook-flash must be transferred
from the FXS to the FXO (HookFlashOption = 4).