Troubleshooting
Avaya 374x DECT Telephones - User Guide 02/2016
151
Synchronization ring broken (Sync) 0x00100001 IPBL X
Reference synchronization signal lost (Sync) 0x00100002 IPBL X
Synchronization lost (Sync) 0x00100004 IPBL X
Unsynchronized to reference (Sync) 0x00100008 IPBL X
Interface down (ipproc) 0x00110000 IPBS/
IPBL
X
Interface not configured (ipproc) 0x00110001 IPBS/
IPBL
X
DHCP server not responding (ipproc) 0x00110002 IPBS/
IPBL
X
Invalid UDP-RTP port base/range (ipproc) 0x00110019 IPBS/
IPBL
X
Invalid UDP-NAT port base/range (ipproc) 0x0011001a IPBS/
IPBL
X
Invalid NAT port base/range (ipproc) 0x0011001b IPBS/
IPBL
X
ARP poisoning detected (ipproc) 0x00110041 IPBS/
IPBL
X
Out of TCP/NAT ports (ipproc) 0x00110046 IPBS/
IPBL
X
Out of TCP ports (ipproc) 0x00110047 IPBS/
IPBL
X
TCP bind error (ipproc)
Local error.
TCP socket was trying to bind itself to a specific
local port number. The port number was found to be
in use by some other socket.
0x00110049 IPBS/
IPBL
X
Out of UDP/RTP ports (ipproc) 0x00110050 IPBS/
IPBL
X
Out of UDP ports (ipproc) 0x00110051 IPBS/
IPBL
X
UDP bind error (ipproc)
Local error.
UDP socket was trying to bind itself to a specific
local port number.
The port number was found to be in use by some
other socket.
0x00110053 IPBS/
IPBL
X
No route to destination (ipproc) 0x0011005a IPBS/
IPBL
X