Parameter name Default value Recommended settings
REGISTERWAIT 900 This parameter represents
number of seconds between
register refreshes. It is
recommended to set the value to
“120” to “180” seconds.
This enables faster recovery
detection of signaling servers.
Related links
Redundancy in a Broadsoft environment on page 278
Redundancy in a Netsapiens environment
In a Netsapiens environment, you can use up to six SIP controllers in a redundancy deployment.
You can use UDP, TCP, or TLS to connect to the SIP controllers.
For more information on the Netsapiens redundancy deployment, see Netsapiens documentation
at HTTPS://NETSAPIENS.COM/.
Related links
SIP server redundancy on page 276
Redundancy parameters - Netsapiens on page 280
Redundancy parameters - Netsapiens
To configure the phone for redundant signaling mode in a Netsapiens environment use
46xxsettings.txt file to set the following parameters:
Parameter name
Default value Required settings
SIPREGPROXYPOLICY simultaneous This must be set to the value
alternate.
SIP_CONTROLLERS_LIST_2 Null This parameter should not be set
and left at default.
Open SIP redundancy does not
support IPv6.
3PCC_SERVER_MODE 0 This parameter should be set to
3.
Table continues…
SIP server redundancy configuration
April 2020 Installing and Administering Avaya J100 series IP Phones in an Open SIP
environment 280