V4.7 | 06/24/2024 | 11165414
119
7.8.36 DeviceTemperatureStatus
Returns the current temperature status of the device.
Name DeviceTemperatureStatus
Category DeviceControl
Interface IEnumeration
Access Read only
Unit -
Values
Exceeded Device operates in critical temperature range.
High Device operates in increased temperature range.
Normal Device operates in normal temperature range.
NomalToUnderrun
(several models)
Device operates in critical low temperature range.
7.8.37 DeviceTemperatureStatusTransition
Temperature threshold for selected status transition in degrees Celsius (C).
Name DeviceTemperatureStatusTransition
Category DeviceControl
Interface IInteger
Access Read / Write
Unit ° C
Values
-128.0 ... 127.0
(depending on DeviceTemperatureStatusTransitionSelector)
7.8.38 DeviceTemperatureStatusTransitionSelector(≥Rel.2only)
Selects which temperature transition is controlled by the DeviceTemperatureStatusTran-
sition feature.
Name DeviceTemperatureStatusTransitionSelector
Category DeviceControl
Interface IEnumeration
Access Read / Write
Unit -
Values
ExceededToNormal
Temperature threshold for transition from status
Exceeded back to status Normal.
HighToExceeded
Temperature threshold for transition from status
High to status Exceeded.
NormalToHigh
Temperature threshold for transition from status
Normal to status High.
NomalToUnderrun
(model dependent)
Temperature threshold for transition from status
Normal to status Underrun.
NormalToHigh
freely programmable value
HighToExceed
fixed value (camera shutdown if exceeded)
NormalToUnderrun
fixed value (camera shutdown if temperature falls
below this value or camera does not start)
ExceedToNormal
(Device Temperature < ExceededToNormal)
freely programmable value
temperature curve
Temperatur
Event:DeviceTemperature-
StatusChanged
Event:DeviceTemperature-
StatusChanged
Event:DeviceTemperature-
StatusChanged
Event:DeviceTemperature-
StatusChanged
Cooling measures
recommended
Heating measures
recommended