7.3.16 ShortExposureTimeEnable
Controls if short exposure time should be supported.
Notice
It is not possible to use the Sequencer when the feature Short Exposure Time Enable
is enabled.
Name ShortExposureTimeEnable
Category AcquisitionControl
Interface IBoolean
Access Read only
Unit -
Values
true = 1 (On)
false = 0 (O󰀨)
7.3.17 TriggerActivation
Species the activation mode of the trigger.
Name TriggerActivation
Category AcqusitionControl
Interface IEnumeration
Access Read / Write
Unit -
Values
FallingEdge
Species that the trigger is considered valid on the 
falling edge of the source signal.
RisingEdge
Species that the trigger is considered valid on the 
rising edge of the source signal.
7.3.18 TriggerDelay
Species the delay in microseconds (us) to apply after the trigger reception before activat-
ing it.
Name TriggerDelay
Category AcqusitionControl
Interface IFloat
Access Read / Write
Unit μs
Values
0 - 2,000,000.000000 (Increment: 1.00)