V4.7 | 06/24/2024 | 11165414
216
7.16.5.6 SIPayloadTransferSize
Expected size of a single Payload Transfer.
Name SIPayloadTransferSize
Category
TansportLayerControl → USB3Vision
Interface IInteger
Access Read only
Unit Byte
Values 0 - 4294967295 (Increment: 1)
7.17 Category: UserSetControl
Category that contains the User Set control features. It allows loading or saving factory or
user-dened settings.
Loading the factory default User Set guarantees a state where a continuous acquisition
can be started using only the mandatory features.
These user sets are stored within the camera and can be loaded, saved and transferred
to other cameras.
By using User Set Default
one of these four user sets can be set as the default, which
means that the camera starts up with these adjusted parameters.
7.17.1 UserSetDefault
Four user sets are available for this camera. User Set 1, User Set 2, User Set 3 are user-
specic and can contain user-denable parameters.
Selects the feature UserSet to load and make active by default when the device is reset.
The factory settings are stored in the user set Default. This is the only user set that cannot
be edited.
Notice
All saved user sets can be set as default.
Name UserSetDefault
Category UserSetControl
Interface IEnumeration
Access Read / Write
Unit -
Values Default Select the factory setting user set.
User Set 1 Select the User Set 1 (available when saved).
User Set 2 Select the User Set 2 (available when saved).
User Set 3 Select the User Set 3 (available when saved).