V4.7 | 06/24/2024 | 11165414
191
7.15.3 SequencerFeatureSelector
Selects the camera features that are controlled by the sequencer.
Name SequencerFeatureSelector
Category SequencerControl
Interface IEnumeration
Access Read / Write
Unit -
Values
CounterDuration
Sets the duration (or number of events) before the
CounterEnd event is generated.
CounterEventAc-
tivation
Selects the Activation mode Event Source signal.
CounterEvent-
Source
Select the events that will be the source to increment
the Counter.
CounterResetAc-
tivation
Selects the Activation mode of the Counter Reset
Source signal.
CounterReset-
Source
Selects the signals that will be the source to reset the
Counter.
ExposureMode Sets the operation mode of the Exposure (or shutter).
ExposureTime Returns the exposure time used to capture the image.
Gain
Controls the selected gain as an absolute physical
value.
Height Height of the image provided by the device (in pixels).
OsetX
Horizontal oset from the origin to the region of inter-
est (in pixels).
OsetY
Vertical oset from the origin to the region of interest
(in pixels).
TriggerMode Controls if the selected trigger is active.
UserOutputValue
Sets the value of the bit selected by UserOutputSe-
lector.
UserOutputVal-
ueAll
Sets the value of all the bits of the User Output reg-
ister.
Width Width of the image provided by the device (in pixels).