4. Installation
4.1 EnvironmentalRequirements
Storage
temperature
VCXG -10 °C (+14 °F) ... +70 °C (+158 °F)
VCXU -10 °C (+14 °F) ... +70 °C (+158 °F)
VCXG.XC -10 °C (+14 °F) ... +70 °C (+158 °F)
VCXG.I -10 °C (+14 °F) ... +70 °C (+158 °F)
VCXG.I.PTP -10 °C (+14 °F) ... +70 °C (+158 °F)
VCXG.I.XT -40 °C (-40 °F) / -30 °C
2)
(-22 °F) ... +70 °C (+158 °F)
Operating
temperature
VCXG 0 °C (41 °F) ... 60 °C (140 °F)
1)
*/** / 65 °C (149 °F)*/**
VCXU 0 °C (41 °F) ... 60 °C (140 °F)
1)
*/** / 65 °C (149 °F)*/**
VCXG.XC 0 °C (32 °F) ... 65 °C (149 °F) */** / 75 °C (167 °F)*/**
VCXG.I 0 °C (32 °F) ... 65 °C (149 °F)*/***
VCXG.I.PTP 0 °C (32 °F) ... 65 °C (149 °F)*/***
VCXG.I.XT -40 °C (-40 °F) / -30 °C
2)
(-22 °F) ... 70 °C (158 °F)*/***
Humidity 10 % ... 90 % non condensing
1)
 VCXU-125M.R / C.R; VCXU-201M.R / C.R
2)
VCXG-201M.R.I.XT / C.R.I.XT
The sensor specication ensures unrestricted use from an operating temperature 
greater than -10 °C (14 °F). Use at temperatures lower than -10 °C (14 °F) may result in
disturbed image acquisition or poorer image quality.
*/ at T (Measurement Point)
/** Ambient temperature in the range above 28 °C (82.4 °F) / 34 °C (93.2 °F) / 32 °C (89.6
°F) / 39 °C (102.2 °F) (depending on camera model) requires heat dissipation measures.
/*** Ambient temperature above 45 °C (113 °F) requires heat dissipation measures.
Notice
Ambient temperature for UL applications
The maximum ambient temperature (all cameras) for UL applications is 40 °C (104 °F).
Air ow (1 m/s) required in all temperature ranges.