7.11.6.4 CalibrationMatrixValueSelector
Selects the gain factor of the calibration matrix.
Name CalibrationMatrixValueSelector
Category
ImageFormatControl → CalibrationControl
Interface IEnumeration
Access Read / Write
Unit -
Values Gain Gain00 ... Gain23
7.11.7 ComponentEnable (MP cameras only)
Controls, if streaming of the component selected by feature ComponentSelector is active.
Name ComponentEnable
Category ImageFormatControl
Interface IBoolean
Access Read only
Unit -
Values
true = 1 (On)
false = 0 (O)
7.11.8 ComponentSelector (MP cameras only)
Selects, which data acquisition component to use.
Name ComponentSelector
Category ImageFormatControl
Interface IEnumeration
Access Read / Write
Unit -
Values PolarizedRaw
Acquisition of polarized light intensity. The polarizing l-
ters are arranged in a 2-by-2 pattern: 135° and 0° on
even lines, 90° and 45° on odd lines. The raw data is
unprocessed.