192
7.15.4 SequencerMode
Controls if the sequencer mechanism is active.
Notice
To use this feature, the features BalanceWhiteAuto (color cameras only) and Sequen-
cerCongurationMode must be o󰀨.
To write this feature, set TLParamsLocked = 0.
Name SequencerMode
Category SequencerControl
Interface IEnumeration
Access Read / Write
Unit -
Values
On Enables the sequencer.
O󰀨 Disables the sequencer.
7.15.5 SequencerPathSelector
Selects the path that contains the settings coming afterward.
Name SequencerPathSelector
Category SequencerControl
Interface IInteger
Access Read / Write
Unit -
Values 0 ... 3 (Increment: 1)
7.15.6 SequencerSetActive
Contains the currently active sequencer set.
Name SequencerSetActive
Category SequencerControl
Interface IInteger
Access Read / Write
Unit -
Values 0 ... 127 (Increment: 1)