Category: AcquisitionControl
This chapter describes all features related to image acquisition, including the trigger and
exposure control.
7.3.1 AcquisitionAbort
The acquisition abort process is a special case in which the current acquisition is stopped.
If an exposure is running, the exposure is aborted immediately and the image is not read
out.
Name AcquisitionAbort
Category AcqusitionControl
Interface ICommand
Access Write only
Unit -
Values -
7.3.2 AcquisitionFrameCount
Number of frames to acquire in MultiFrame Acquisition mode
Name AcquisitionFrameCount
Category AcqusitionControl
Interface IInteger
Access Read / Write
Unit -
Values 1 - 65535 (Increment: 1)
7.3.3 AcquisitionFrameRate
Controls the acquisition rate (in Hertz) at which the frames are captured.
Notice
For cameras that use the PTP functionality, the generation of the frame rate is based on
the synchronized timestamp. This ensures the synchronous recording of frames.
The PtpServoStatus feature must be locked to use this functionality.
Name AcquisitionFrameRate
Category AcqusitionControl
Interface IFloat
Access Read / Write
Unit Hz
Values dedends on camera