7.10.20.1 DeviceTemperaturStatusChanged
To prevent damage on the hardware due to high temperatures, the camera is equipped 
with an emergency shutdown. The DeviceTemperatureStatusTransitionSelector (Catego-
ry: Device Control) feature allows you to select di󰀨erent thresholds for temperatures:
NormalToHigh: freely programmable value
HighToExeeded: xed value (camera shutdown if exceeded)
ExeededToNormal: freely programmable value, temperature for error-free re-ac- 
tivation of the camera.
DeviceTemperatureUnderrun (several models): xed value (camera shutdown if 
value falls below)
In the DeviceTemperatureStatusTransitionfeature, the temperatures for the programma-
ble temperature transitions are set.
The Event DeviceTemperatureStatusChanged is always generated when DeviceTem-
peratureStatus changes.
If the temperature rises above the value set at HighToExceed
, the DeviceTemperatureEx-
ceeded feature is set to True, the image recording is stopped, and the LED is set to red.
If the temperature falls below the DeviceTemperatureUnderrun value,  the  DeviceTem-
peratureUnderrun function is set to True, image recording is stopped and the LED lights 
up red.
For further use, the camera must disconnected from the power supply after cooling down 
or heating a device reset should be carried out.
The su󰀩cient cooling / heating is recognizable when the event DeviceTemperatureStatus-
Changed (Device Temperature < ExceededToNormal) / (Device Temperature > Device-
TemperatureUnderrun) is output.
NormalToHigh
freely programmable value
HighToExceed
fixed value (camera shutdown if exceeded)
NormalToUnderrun
fixed value (camera shutdown if temperature falls
below this value or camera does not start)
ExceedToNormal
(Device Temperature < ExceededToNormal)
freely programmable value
temperature curve
Time
Temperature
Event:DeviceTemperature-
StatusChanged
Event:DeviceTemperature-
StatusChanged
Event:DeviceTemperature-
StatusChanged
Event:DeviceTemperature-
StatusChanged
Cooling measures
recommended
Heating measures
recommended
7.10.1 EventNotication
Activate or deactivate the notication to the host application of the occurrence of the se-
lected Event.
Name EventNotication
Category EventControl
Interface IEnumeration
Access Read / Write
Unit -
Values
Off
The selected Event notication is disabled.
On The selected Event notication is enabled.