121
7.8.43 DeviceVersion
Version of the device.
Name DeviceVersion
Category DeviceControl
Interface IString
Access Read only
Unit -
Values e.g. R1.0.0
7.8.44 ReadOutTime
Readout time in µs for current format settings.
Notice
Read Out Time depends on:
▪ O󰀨setY
▪ Height
▪ PixelFormat
▪ SensorBinning
Name ReadOutTime
Category DeviceControl
Interface IInteger
Access Read only
Unit µs
Values 0 ... 65535 (Increment: 1)
7.8.45 TimestampLatch
Latches the current timestamp counter into TimestampLatchValue.
Name TimestampLatch
Category DeviceControl
Interface ICommand
Access Write only
Unit -
Values -
7.8.46 TimestampLatchValue
Returns the latched value of the timestamp counter.
Name TimestampLatchValue
Category DeviceControl
Interface IInteger
Access Read only
Unit ns
Values
≥0 (Increment: 8 (GigE) / 10 (USB))