Specications 80
General
Remote Sense
Compensation
1 V
Command
Response Time
(4)
10 ms
Power Factor
0.98 / 115 VAC
0.94 / 230 VAC
I/O Interfaces
USB (USBTMC & USBVCP),
LAN (1.5 LXI device
specication 2016),
GPIB (optional)
AC Line Input
100 VAC to 240 VAC ±
10%, 47 Hz to 63 Hz
Maximum Rated Input
Power (9240 /9241)
200 VA
Maximum Rated
Input Power (9242)
300 VA
Temperature
Ratings
Operation 32 °F to 104 °F (0 °C to 40 °C)
Storage 14 °F to 158 °F (-10 °C to 70 °C)
Dimensions (W x H x D) 8.4” x 3.5” x 13” (213 x 88 x 330 mm)
Weight 11 lbs (5 kg)
Warranty 3 Years
Standard Accessories
Power cord, test report &
certicate of calibration
Optional Accessories Rack mount kit (RK2US)
Regulatory Compliance
Safety
Low Voltage Directive (LVD) 2014/35/EU,
EN61010-1:2010, cTUVus certication
mark
(5)
fullls US (UL 61010-1:2012) and
Canadian (CAN/CSA-C22.2 NO.
61010-1-12) safety standards
Electromagnetic
Compatibility
EMC Directive 2014/30/EU,
EN61326-1:2013
(1) With remote sense terminal connected.
(2) From 10% to 90% or from 90% to 10% of total voltage excursion.
(3) Time for output voltage to recover within 0.5% of its rated output for a load
change 50-100% of full load.
(4) Typical time required for output to begin to change following receipt of
command data.
(5) Tested and certied by a Nationally Recognized Testing Laboratory
(NRTL), accredited by OSHA