VPLC / PLC 14108/10
08/10 VPLC / PLC 141
Table of functions Index 1 Index 2 Index 3 Index 4
FT instruction
1343
2 - OR 10 - RS Flip-Flop
Superior
1 - AND 0 - Off (last table
item)
FT input 1 1344
2004 - FT input
buffer 4
2101 - Outp.1
instruction 1
2006 - FT input
buffer 6
7 – FALSE
FT input 2 1345
2003 - FT input
buffer 3
2009 - FT input
buffer 9
2005 - FT input
buffer 5
7 – FALSE
FT input 3 1346
2002 - FT input
buffer 2
7 – FALSE 2201 - Outp.1
instruction 1
1)
7 – FALSE
FT input 4 1347
7 – FALSE 7 – FALSE 2202 - Outp.1
instruction 2
2)
7 – FALSE
FT-Target Output
1
1350
0 - Output not
usable globally
2402 - FT-
Output buffer 2
2401 - FT-
Output buffer 1
0 - Output not
usable globally
FT-Target Output
2
1351
0 - Output not
usable globally
0 - Output not
usable globally
0 - Output not
usable globally
0 - Output not
usable globally
1)
Inverted output of function 1 (in this example of OR function)
2)
Inverted output of function 2 (in this example of RX-Flip-Flop)
The outputs of the FT-instructions are available as sources and can be linked to the inputs of
other functions or output via digital outputs.
Example:
Linking of AND function output with Start Clockwise Function, parameter Start clockwise
068 = "2402 - FT output buffer 2"
Linking of RS-Flip-Flop output with digital output 1; Parameter
Operation mode digital out-
put 1
530 = "80 – FT-Output buffer 1"

Table of Contents

Other manuals for BONFIGLIOLI Agile

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the BONFIGLIOLI Agile and is the answer not in the manual?

BONFIGLIOLI Agile Specifications

General IconGeneral
BrandBONFIGLIOLI
ModelAgile
CategoryDC Drives
LanguageEnglish

Related product manuals