VPLC / PLC 7108/10
08/10 VPLC / PLC 71
4.7 Digital multiplexer
4.7.1 [90] Digital Multiplexer (Data Set Number)
Type Function
Type Function
I1
b Input data set 1
O1
b output O1
I2
b Input data set 2
O2
b
negated output O2 =
1O
I3
b Input data set 3
P1
I4
b Input data set 4
P2
Description:
Depending on the current data set, the input values are forwarded to the outputs .
Parameter
Active data set 249 shows the selected data set.
Digital Multiplexer (Data Set Number)
Active Data
Set
249
2401
1
2
3
4
E1
E2
E3
E4
249
Active
D
ata Set
2401
A1
A1
4.8 Switch
4.8.1 [91] Switch Data Set
Type Function
Type Function
I1
b Input 1 (highest priority)
O1
- -
I2
b Input 2
O2
- -
I3
b Input 3
P1
- -
I4
b Input 4 (lowest priority)
P2
-
-
Description:
A data set is selected via the input values.
Switch data set
I1 I2 I3 I4 Data Set
1 x x x 1
0 1 x x 2
0 0 1 x 3
0 0 0 1 4
0 0 0 0 Data set via contacts

Table of Contents

Other manuals for BONFIGLIOLI Agile

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the BONFIGLIOLI Agile and is the answer not in the manual?

BONFIGLIOLI Agile Specifications

General IconGeneral
BrandBONFIGLIOLI
ModelAgile
CategoryDC Drives
LanguageEnglish

Related product manuals