Description Symbol Unit
HLR01.2N-01
K0-N28R0-
E-007-NNNN
Preliminary
HLR01.2N-01
K0-N68R0-
E-007-NNNN
Preliminary
HLR01.2N-0K
06-N100R-
E-003-NNNN
HLR01.2N-0K
06-N180R-
E-007-NNNN
Mass m kg 3.96 0.52
Nominal braking resistor
R
DC_Bleed‐
er
ohm 28.00 68.00 100.00 180.00
Braking resistor continuous power
P
BD
kW 1.00 0.06
Braking resistor peak power
P
BS
kW 25.82 8.96 1.38 3.39
Regenerative power to be absor‐
bed
W
R_max
kWs 30.00 10.00 1.00 2.40
Maximum allowed on-time duty
t
on_max
s 1.16 1.11 0.72 0.71
Minimum allowed cycle time
T
cycl
s 33.30 9.90 16.50 40.10
Cooling type natural
Volumetric capacity of forced cool‐
ing
V
m
3
/h
-
Temperature increase with mini‐
mum distances d
bot
; d
top
; P
BD
ΔT K -
Minimum distance on the top of
the device
1)
d
top
mm 200 150
Minimum distance on the bottom
of the device
2)
d
bot
mm 200 150
Horizontal spacing on the device
3)
d
hor
mm 200 50
Allowed range tightening torque M Nm -
Required wire size in accordance
with NFPA 79 and UL 508 A (in‐
ternal wiring);
4)
A
LN
AWG 16
Last modification: 2014-05-26
1) 2) 3) See fig. "Air intake and air outlet at device"
4) Copper wire; PVC-insulation (conductor temperature 90 °C);
table 28.1; T
a
≤ 40 °C
Tab. 8-33: HLR - technical data - currents, voltages, power
Bosch Rexroth AG DOK-INDRV*-HCS01******-PR05-EN-P302/341
Rexroth IndraDrive CsDrive Systems with HCS01
Cables, accessories, additional components