Type Cross section of power core Leakage capacitance
mm
2
C
Y_K_typ
nF/m
INK0667 35,0 1,2
INK0668 50,0 1,3
Last modification: 2007-11-08
Tab. 11-9: INK - Technical Data (Excerpt)
Data Sheet Excerpt- Bulk Cables
Type Cross section of power core Leakage capacitance
C
Y_K_typ
mm
2
nF/m
REH0800 2,5 0,2
Tab. 11-10: REH - Technical Data (Excerpt)
Approximate calculation is allowed with the following values:
● Cross section 1 … 6 mm
2
: 1 nF/m
● Cross section 10 … 50 mm
2
: 1.2 nF/m
DOK-INDRV*-HCS01******-PR05-EN-P Bosch Rexroth AG 329/341