Mains Type and Mains Voltage
IT mains
Mains grounded via outer conductor
TN-S mains
TN-C mains
TT mains
Mains voltage ≤ 3 AC 230V Mains voltage 3 AC 230 … 500 V
To be noticed with 1-phase mains volt‐
age: See table "Mains Supply"
No transformer required Isolating transformer with grounded
neutral point required
HCS01.1E-W0003-A-02
HCS01.1E-W0006-A-02
HCS01.1E-W0009-A-02
HCS01.1E-W0013-A-02
HCS01.1E-W0018-A-02
HCS01.1E-W0005-A-03
HCS01.1E-W0008-A-03
HCS01.1E-W0018-A-03
HCS01.1E-W0028-A-03
HCS01.1E-W0054-A-03
HCS01.1E-W0005-A-03
HCS01.1E-W0008-A-03
HCS01.1E-W0018-A-03
HCS01.1E-W0028-A-03
HCS01.1E-W0054-A-03
HCS01.1E-W0003-A-02
HCS01.1E-W0006-A-02
HCS01.1E-W0009-A-02
HCS01.1E-W0013-A-02
HCS01.1E-W0018-A-02
HCS01.1E-W0005-A-03
HCS01.1E-W0008-A-03
HCS01.1E-W0018-A-03
HCS01.1E-W0028-A-03
HCS01.1E-W0054-A-03
Tab. 4-1: Mains Type and Mains Voltage
Mains Supply
1-phase
1)
3-phase
1 AC 110 … 230 V 3 AC 200 ... 500 V
Autotransformer -
3 AC 110 … 230 V -
HCS01.1E-W0003-A-02
HCS01.1E-W0006-A-02
HCS01.1E-W0009-A-02
HCS01.1E-W0013-A-02
HCS01.1E-W0018-A-02
HCS01.1E-W0005-A-03
HCS01.1E-W0008-A-03
HCS01.1E-W0018-A-03
HCS01.1E-W0028-A-03
HCS01.1E-W0054-A-03
Mains supply
Individual supply Individual supply
Group supply
Central supply
1)
With 1-phase mains supply, you can connect the mains supply
line to connector X3 at L1, L2 or L3
Tab. 4-2: Mains Supply
DC bus coupling
If energy compensation is to be available between the individual devices, the
DC buses of these devices must be coupled. DC bus coupling restricts the
selection of HCS01 converters.
See also chapter 4.6.4 "DC bus coupling" on page 105.
Bosch Rexroth AG DOK-INDRV*-HCS01******-PR05-EN-P42/341
Rexroth IndraDrive CsDrive Systems with HCS01
Combining the individual components