HCS01.1E-W0003, -W0006, -W0009, -W0013
Clock frequency
[kHz]
Maximum leakage capacitance
(Motor + cable) per device [nF]
Motor cable length
[m]
4 33 40
8 17 20
12 13 15
16 5 5
Tab. 4-32: Clock frequency, leakage capacitance, motor cable length
HCS01.1E-W0005, -W0008
Clock frequency
[kHz]
Maximum leakage capacitance
(Motor + cable) per device [nF]
Motor cable length
[m]
4 34 40
8 18 20
12 14 15
16 6 5
Tab. 4-33: Clock frequency, leakage capacitance, motor cable length
HCS01.1E-W0018, -W0028
Clock frequency
[kHz]
Maximum leakage capacitance
(Motor + cable) per device [nF]
Motor cable length
[m]
4 40 40
8 24 20
12 20 15
16 12 5
Tab. 4-34: Clock frequency, leakage capacitance, motor cable length
HCS01.1E-W0054
Clock frequency
[kHz]
Maximum leakage capacitance
(Motor + cable) per device [nF]
Motor cable length
[m]
4 85 75
8 43 38
12 30 25
Tab. 4-35: Clock frequency, leakage capacitance, motor cable length
Select the appropriate mains connection (supply unit/converter, mains choke,
mains filter) from the tables in the corresponding chapter (see chapter "Com‐
bining transformer, mains filter and mains choke" on page 103).
DOK-INDRV*-HCS01******-PR05-EN-P Bosch Rexroth AG 97/341
Rexroth IndraDrive CsDrive Systems with HCS01
Combining the individual components

Table of Contents