INSTALLATION MANUAL
ELECTRICAL INTERFACES – 916 I TYPE C24
916 i TYPE C24
The seals supplied with the Fusebox must be inserted into the X1,X2 and X3 Connector
(Fusebox side) to enable a good connection between plug and socket and thus avoid un-
necessary vibrations and misalignment of connector pins.
Fusebox –X1, X2
Connector
The X1 and X2 ensure the power distribution to the EMS System. Both plugs must be con-
nected with mating sockets on the (engine-) wiring harness. The connectors are not inter-
changeable and are marked on the wiring harness side.
Fusebox – X3
Connector
Terminal 1 enables the EMS to be supplied with an external power source (e.g. in case
the internal power supply fails supplying the EMS).
Terminal
Interface
Parameter
Min. Max. Nominal
1 Input voltage: 24 V
Input load:
230 W DC cont.
290 W DC peak
2 Plugged, do not pierce the plug seal.
3 Plugged, do not pierce the plug seal.
NOTICE
In failure conditions the output voltage can exceed the specified limits.
Effectivity: 916 i A / C24
Edition 0/Rev. 1
24–00–00
Page 13
December 01 2023