EasyManua.ls Logo

Campbell CR850 - Table 46. Prtcalc() Type-Code-2 Sensor; Table 47. Prtcalc() Type-Code-3 Sensor

Campbell CR850
566 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Section 7. Installation
256
Table 45. PRTCalc() Type-Code-1 Sensor
IEC 60751:2008 (IEC 751), alpha = 0.00385. Now internationally
adopted and written into standards ASTM E1137-04, JIS 1604:1997,
EN 60751 and others. This type code is also used with probes
compliant with older standards DIN43760, BS1904, and others.
(Reference: IEC 60751. ASTM E1137)
Constant Coefficient
e 1.7584810E-05
f -1.1550000E-06
g 1.7909000E+00
h -2.9236300E+00
i 9.1455000E+00
j 2.5581900E+02
Table 46. PRTCalc() Type-Code-2 Sensor
US Industrial Standard, alpha = 0.00392 (Reference: Logan
Enterprises)
Constant Coefficient
a 3.9786300E-03
d -2.3452400E-06
e 1.8174740E-05
f -1.1726200E-06
g 1.7043690E+00
h -2.7795010E+00
i 8.8078440E+00
j 2.5129740E+02
Table 47. PRTCalc() Type-Code-3 Sensor
US Industrial Standard, alpha = 0.00391 (Reference: OMIL R84
(2003))
Constant Coefficient
a 3.9690000E-03
d -2.3364000E-06
e 1.8089360E-05
f -1.1682000E-06
g 1.7010560E+00
h -2.6953500E+00

Table of Contents