Section 6. CR800 Specifications
1.1
CR800specificationsarevalidfrom─25°to50°Cinnoncondensingenvironmentsunlessotherwisespecified.Recalibrationisrecommendedeverytwoyears.Criticalspecificationsandsystem
configurationsshouldbeconfirmedwithaCampbellScientificapplicationsengineerbeforepurchase.
2.0
PROGRAMEXECUTIONRATE
2.1
10mstoonedayat10msincrements
3.0
ANALOGINPUTS(SE1–6,DIFF1–3)
3.0.1
Threedifferential(DIFF)orsixsingleended(SE)individually
configuredinputchannels.Channelexpansionprovidedby
optionalanalogmultiplexers.
3.1.0
RANGESandRESOLUTION:Withreferencetothefollowingtable,
basicresolution(BasicRes)istheresolutionofasingleA/D
(p.
425)conversion.ADIFFmeasurementwithinputreversalhas
better(finer)resolutionbytwicethanBasicRes.
3.1.1‐‐810
Range(mV)
1
DIFF
Res(μV)
2
Basic
Res(μV)
±5000
±2500
±250
±25
±7.5
±2.5
667
333
33.3
3.33
1.0
0.33
1333
667
66.7
6.7
2.0
0.67
1
Rangeoverheadof≈9%onallrangesguaranteesfullscale
voltagewillnotcauseoverrange.
2
ResolutionofDIFFmeasurementswithinputreversal.
3.2‐‐810
ANALOGINPUTACCURACY
3
:
±(0.06%ofreading+offset
3
),to40°C
±(0.12%ofreading+offset
3
),‐25°to50°C
±(0.18%ofreading+offset
3
),‐55°to85°C(XTonly)
3.2.1
3
Accuracydoesnotincludesensorandmeasurementnoise.Offset
definitions:
Offset=1.5xBasicRes+1.0µV(forDIFFmeasurementw/input
reversal)
Offset=3xBasicRes+2.0µV(forDIFFmeasurementw/oinput
reversal)
Offset=3xBasicRes+3.0µV(forSEmeasurement)
3.3
ANALOGMEASUREMENTSPEED:
3.3.1‐‐810
‐‐‐TotalTime
4
‐‐‐
Inte‐
gration
Type
Code
Inte‐
gration
Time
Settling
Time
SE
with
no
Rev
DIFF
with
Input
Rev
250
_60Hz
5
_50Hz
5
250µs
16.67ms
20.00ms
450µs
3ms
3ms
1ms
20ms
25ms
12ms
40ms
50ms
4
Includes250μsforconversiontoengineeringunits.
5
AClinenoisefilter
3.4
INPUTNOISEVOLTAGE:ForDIFFmeasurementswithinput
reversalon±2.5mVinputrange(digitalresolutiondominatesfor
higherranges):
250μsIntegration:0.34μVRMS
50/60HzIntegration:0.19μVRMS
INPUTLIMITS:±5Vdc
DCCOMMONMODEREJECTION:>100dB
NORMALMODEREJECTION:70dB@60Hzwhenusing60Hz
rejection
INPUTVOLTAGERANGEW/OMEASUREMENTCORRUPTION:±8.6
Vdcmax.
SUSTAINEDINPUTVOLTAGEW/ODAMAGE:±16Vdcmax.
INPUTCURRENT:±1nAtypical,±6nAmax.@50°C;±90nA@85°C
INPUTRESISTANCE:20GΩtypical
ACCURACYOFBUILTINREFERENCEJUNCTIONTHERMISTOR(for
thermocouplemeasurements):
±0.3°C,‐25°to50°C
±0.8°C,‐55°to85°C(XTonly)
4.0
ANALOGOUTPUTS(VX1–2)
4.0.1‐‐8
Twoswitchedvoltageoutputssequentiallyactiveonlyduring
measurement.
4.0.2
RANGESANDRESOLUTION:
4.1‐‐810
Channel
Range
Resolu‐
tion
Current
Source
/Sink
(VX1–2) ±2.5Vdc 0.67mV ±25mA
4.2‐‐810
ANALOGOUTPUTACCURACY(VX):
±(0.06%ofsetting+0.8mV,to40°C
±(0.12%ofsetting+0.8mV,‐25°to50°C
±(0.18%ofsetting+0.8mV,‐55°to85°C(XTonly)
4.4
VXFREQUENCYSWEEPFUNCTION:Switchedoutputsprovidea
programmablesweptfrequency,0to2500mVsquarewavesfor
excitingvibratingwiretransducers.
3.5.0
PERIODAVERAGE
3.5.0a
Anyofthe6SEanaloginputscanbeusedforperiodaveraging.
Accuracyis±(0.01%ofreading+resolution),whereresolution
is136nsdividedbythespecifiednumberofcyclestobe
measured.
INPUTAMPLITUDEANDFREQUENCY:
3.5.1‐‐810
Volt‐
Input
Signal
PeakPeak
Min
Pulse
Max
age
Gain
Range
Code
Min
mV
6
Max
V
7
Width
µs
Freq
kHz
8
1
10
33
100
mV250
mV25
mV7_5
mV2_5
500
10
5
2
10
2
2
2
2.5
10
62
100
200
50
8
5
6
SignaltobecenteredaroundThreshold(seePeriodAvg()
instruction).
7
Signaltobecenteredaroundground.
8
Themaximumfrequency=1/(twiceminimumpulsewidth)
for50%ofdutycyclesignals.
5.0
RATIOMETRICMEASUREMENTS
5.1‐‐810
MEASUREMENTTYPES:TheCR800providesratiometric
resistancemeasurementsusingvoltageexcitation.Three
switchedvoltageexcitationoutputsareavailablefor
measurementoffour‐andsixwirefullbridges,andtwo,
three,andfourwirehalfbridges.Optionalexcitationpolarity
reversalminimizesdcerrors.
5.2‐‐810
RATIOMETRICMEASUREMENTACCURACY
9,11
NoteImportantassumptionsoutlinedinfootnote9:
±(0.04%ofVoltageMeasurement+Offset
12
)
5.2.1
9
Accuracyspecificationassumesexcitationreversalfor
excitationvoltages<1000mV.Assumptiondoesnotinclude
bridgeresistorerrorsandsensorandmeasurementnoise.
11
Estimatedaccuracy,∆X(whereXisvaluereturnedfrom
measurementwithMultiplier=1,Offset=0):
BRHalf()Instruction:∆X=∆V
1/
V
X
.
BRFull()Instruction
:
X=1000x∆V
1/
V
X
,expressedasmV•V
1
.
Note∆V
1
iscalculatedfromtheratiometricmeasurement
accuracy.SeemanualsectionResistanceMeasurements
(p.
291)formoreinformation.
12
Offsetdefinitions:
Offset=1.5xBasicRes+1.0µV(forDIFFmeasurementw/
inputreversal)
Offset=3xBasicRes+2.0µV(forDIFFmeasurementw/o
inputreversal)
Offset=3xBasicRes+3.0µV(forSEmeasurement)
NoteExcitationreversalreducesoffsetsbyafactoroftw
o.
6.0
PULSECOUNTERS(P1–2)
6.0.1
Twoinputsindividuallyselectableforswitchclosure,high
frequencypulse,orlowlevelac.Independent24bitcounters
foreachinput.
6.1
MAXIMUMCOUNTSPERSCAN:16.7x10
6
6.2
SWITCHCLOSUREMODE:
MinimumSwitchClosedTime:5ms
MinimumSwitchOpenTime:6ms
Max.BounceTime:1msopenwithoutbeingcounted
6.3
HIGHFREQUENCYPULSEMODE:
MaximumInputFrequency:250kHz
MaximumInputVoltage:±20V
VoltageThresholds:Countupontransitionfrombelow0.9Vto
above2.2Vafterinputfilterwith1.2μstimeconstant.
6.4
LOWLEVELACMODE:Intern alaccouplingremovesdcoffsets
upto±0.5Vdc.
InputHysteresis:12mVRMS@1Hz
MaximumacInputVoltage:±20V
MinimumacInputVoltage:
6.4.1
Sinewave(mVRMS) Range(Hz)
20
200
2000
5000
1.0to20
0.5to200
0.3to10,000
0.3to20,000
7.0
DIGITALI/OPORTS(C14)
7.0.1
Fourportssoftwareselectableasbinaryinputsorcontrol
outputs.Provideon/off,pulsewidthmodulation,edgetiming,
subroutineinterrupts/wakeup,switchclosurepulsecounting,
highfrequencypulsecounting,asynchronouscommunications
(UARTs),andSDI12communications.SDMcommunications
arealsosupported.
7.0
DIGITALI/OPORTS(C14)
7.0.1
Fourportssoftwareselectableasbinaryinputsorcontrol
outputs.Provideon/off,pulsewidthmodulation,edgetiming,
subroutineinterrupts/wakeup,switchclosurepulsecounting,
highfrequencypulsecounting,asynchronouscommunications
(UARTs),andSDI12communications.SDMcommunicationsare
alsosupported.
7.1
LOWFREQUENCYMODEMAX:<1kHz
7.2
HIGHFREQUENCYMODEMAX:400kHz
7.3
SWITCHCLOSUREFREQUENCYMAX:150Hz
7.4
EDGETIMINGRESOLUTION:
7.5
OUTPUTVOLTAGES(noload):high5.0V±0.1V;lo w<0.1V
7.6
OUTPUTRESISTANCE:330Ω
7.7
INPUTSTATE:high3.8to16V;low‐8.0to1.2 V
7.8
INPUTHYSTERISIS:1.4V
7.9
INPUTRESISTANCE:
100kΩwithinputs<6.2Vdc
220Ωwithinputs≥6.2Vdc
7.10
SERIALDEVICE/RS232SUPPORT:0to5VdcUART
7.12
SWITCHED12Vdc(SW12)
Oneindependent12Vdcunregulatedterminalswitchedonand
offunderprogramcontrol.Thermalfuseholdcurrent=900mA
at20°C,650mAat50°C,and360mAat85°C.
8.0
CECOMPLIANCE
8.1
STANDARD(S)TOWHICHCONFORMITYISDECLARED:
IEC61326:2002
9.0
COMMUNICATION
9.1
RS232PORTS:
DCEninepin:(notelectricallyisolated)forcomputerconnection
orconnectionofmodemsnotmanufacturedbyCampbell
Scientific.
COM1toCOM2:twoindependentTx/Rxpairsoncontrolports
(nonisolated);0to5VdcUART
BaudRate:selectablefrom300bpsto115.2kbps.
DefaultFormat:eightdatabits;onest
opbits;noparity.
OptionalFormats:sevendatabits;twostopbits;odd,even
parity.
9.2
CSI/OPORT:Interfacewithtelecommunicationsperipherals
manufacturedbyCampbellScientific.
9.3
SDI12:DigitalcontrolportsC1,C3areindividuallyconfigurable
andmeetSDI12Standardv.1.3fordataloggermode.Uptoten
SDI12sensorsaresupportedperport.
9.5
PROTOCOLSSUPPORTED:PakBus,AES128EncryptedPakBus,
Modbus,DNP3,FTP,HTTP,XML,HTML,POP3,SMTP,Telnet,
NTCIP,NTP,WebAPI,SDI12,SDM.
10.0
SYSTEM
10.1
PROCESSOR:RenesasH8S2322(16bitCPUwith32bitinternal
corerunningat7.3MHz)
10.2
MEMORY:2MBofflashforoperatingsystem;4MBofbattery
backedSRAMforCPUusage,programstorage,andfinaldata
storage.
10.3
REALTIMECLOCKACCURACY:±3min.peryear.Correctionvia
GPSoptional.
10.4
RTCCLOCKRESOLUTION:10ms
11.0
SYSTEMPOWERREQUIREMENTS
11.1
VOLTAGE:9.6to16Vdc
11.2‐‐810
INTERNALBATTERY:1200mAhrlithiumbatteryforclockand
SRAMbackup.Typicallyprovidesthreeyearsofbackup.
11.3
EXTERNALBATTERIES:Optional12Vdcnominalalkalineand
rechargeableavailable.Powerconnectionisreversepolarity
protected.
11.4
TYPICALCURRENTDRAINat12Vdc:
SleepMode:0.7mAtypical;0.9mAmaximum
1HzSampleRate(onefastSEmeas.)mA
100HzSampleRate(onefastSEmeas.):16mA
100HzSampleRate(onefastSEmeas.withRS232
communications):28mA
Activeexternalkeyboarddisplayadds7mA(
100mAwith
backlighton).
12.0
PHYSICAL
12.1
DIMENSIONS:241x104x51mm(9.5x4.1x2in.);additional
clearancerequiredforcablesandleads.
12.2
MASS/WEIGHT:0.7kg/1.5lbs
13.0
WARRANTY
13.1
Warrantyisstatedinthepublishedpricelistandinopening
pagesofthisandotherusermanuals.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Campbell CR850 and is the answer not in the manual?

Campbell CR850 Specifications

General IconGeneral
BrandCampbell
ModelCR850
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals