Section 8. Operation
366
JSON Response
When json is entered in the DataQuery format parameter, the response will be
formatted as CSIJSON. Following is an example response:
{
.."head": {
...."transaction": 0,
...."signature": 26426,
...."environment": {
......"station_name": "Q2",
......"table_name": "BallastLine",
......"model": "CR1000",
......"serial_no": "18583",
......"os_version": "CR1000.Std.25",
......"prog_name": "CPU:IndianaHarbor_081712.CR1"
....},
...."fields": [{
......"name": "Induced_Water",
......"type": "xsd:float",
......"process": "Smp",
......"settable": false}]
},
......"data": [{
......"time": "2012-08-21T22:41:50",
......"no": 104,
......"vals": [66]
},{
......"time": "2012-08-21T22:42:00",
......"no": 105,
......"vals": [66]
},{
......"time": "2012-08-21T22:42:10",
......"no": 106,
......"vals": [66]
},{
......"time": "2012-08-21T22:42:20",
......"no": 107,
......"vals": [66]
},{
......"time": "2012-08-21T22:42:30",
......"no": 108,
......"vals": [66]
}]}
TOA5 Response
When toa5 is entered in the DataQuery format parameter, the response will be
formated as Campbell Scientific TOA5. Following is an example response:
"TOA5","TXSoil","CR1000","No_SN","CR1000.Std.25","TexasRun_1b.CR
2","12645","_1Hr"
"TIMESTAMP","RECORD","ID","_6_inch","One","Two","Three","Temp_F_
Avg","Rain_in_Tot"
"TS","RN","","","","","","",""
"","","Smp","Smp","Smp","Smp","Smp","Avg","Tot"
"2012-05-03 17:00:00",0,0,-0.8949984,-0.95232,-0.8949984,-
0.8637322,2.144136,0.09999999
"2012-05-03 18:00:00",1,0,-0.9106316,-0.9731642,-0.9210536,-
0.8845763,72.56885,0