EasyManuals Logo

Cisco Catalyst 3750-E User Manual

Cisco Catalyst 3750-E
1414 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #168 background imageLoading...
Page #168 background image
5-32
Catalyst 3750-E and 3560-E Switch Software Configuration Guide
OL-9775-08
Chapter 5 Managing Switch Stacks
Troubleshooting Stacks
On a Catalyst 3750-E or 3750-X switch:
Switch# show platform stack ports buffer
Stack Debug Event Data Trace
===============
===============================================
Event type LINK: Link status change
Event type RAC: RAC changes to Not OK
Event type SYNC: Sync changes to Not OK
==============================================================
Event Stack Stack PCS Info Ctrl-Status Loopback Cable
Count Port IOS / HW length
========= ===== =================================== =========== ======== ========
Event type: LIN
K OK Stack Port 1
0000000014 1 FF01FF00 860204A7 5555FFFF 00000000 0CE60CA6 No /No 50 cm
0000000014 2 FF01FF00 85020823 AAAAFFFF 00000000 0CE60CA6 No /No 3 m
Event type: RAC
0000000015 1 FF01FF00 860204A7 5555FFFF 00000000 0CE60CA6 No /No 50 cm
0000000015 2 FF01FF00 85020823 AAAAFFFF 00000000 0CE60CA6 No /No 3 m
Event type: LINK OK Stack Port 2
0000000029 1 FF01FF00 860204A7 5555FFFF 00000000 1CE61CE6 No /No 50 cm
0000000029 2 FF01FF00 86020823 AAAAFFFF 00000000 1CE61CE6 No /No 3 m
Event type: RAC
0000000030 1 FF01FF00 860204A7 5555FFFF 00000000 1CE61CE6 No /No 50 cm
0000000030 2 FF01FF00 86020823 AAAAFFFF 00000000 1CE61CE6 No /No 3 m
Event type: LINK NOT OK Stack Port 1
0000009732 1 FF01FF00 00015B12 5555FFFF A49CFFFF 0C140CE4 No /No 50 cm
0000009732 2 FF01FF00 86020823 AAAAFFFF 00000000 0C140CE4 No /No 3 m
Event type: RAC
0000009733 1 FF01FF00 00015B4A 5555FFFF A49CFFFF 0C140CE4 No /No 50 cm
0000009733 2 FF01FF00 86020823 AAAAFFFF 00000000 0C140CE4 No /No 3 m
Event type: LINK NOT OK Stack Port 2
0000010119 1 FF01FF00 00010E69 25953FFF FFFFFFFF 0C140C14 No /Yes No cable
0000010119 2 FF01FF00 0001D98C 81AAC7FF 0300FFFF 0C140C14 No /No 3 m
Event type: RAC
0000010120 1 FF01FF00 00010EEA 25953FFF FFFFFFFF 0C140C14 No /Yes No cable
0000010120 2 FF01FF00 0001DA0C 81AAC7FF 0300FFFF 0C140C14 No /No 3 m
Finding a Disconnected Stack Cable
Stack cables connect all stack members. Port 2 on Switch 1 connects to Port 1 on Switch 2.
This is the port status for the members:
Switch# show switch stack-ports summary
Switch#/ Stack Neighbor Cable Link Link Sync # In
Port# Port Length OK Active OK Changes Loopback
Status To LinkOK
-------- ------ -------- -------- ---- ------ ---- --------- --------
1/1 OK 2 50 cm Yes Yes Yes 0 No
1/2 OK 2 50 cm Yes Yes Yes 0 No
2/1 OK 1 50 cm Yes Yes Yes 0 No
2/2 OK 1 50 cm Yes Yes Yes 0 No
If you disconnect the cable from Port 2 on Switch 1, these messages appear:
%STACKMGR-4-STACK_LINK_CHANGE: Stack Port 1 Switch 2 has changed to state DOWN
%STACKMGR-4-STACK_LINK_CHANGE: Stack Port 2 Switch 1 has changed to state DOWN
This is now the port status:
Switch# show switch stack-ports summary

Table of Contents

Other manuals for Cisco Catalyst 3750-E

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco Catalyst 3750-E and is the answer not in the manual?

Cisco Catalyst 3750-E Specifications

General IconGeneral
SeriesCatalyst 3750-E
Switching Capacity32 Gbps
Stacking Bandwidth32 Gbps
StackWise PlusYes
Layer SupportLayer 3
MAC Address Table Size12, 000 entries
RAM256 MB
Flash Memory64 MB
Memory256 MB DRAM, 64 MB Flash
Operating Temperature32 to 113°F (0 to 45°C)
Ports48 10/100/1000 Ethernet ports
Form FactorRack-mountable
Jumbo Frame SupportYes
Input Voltage100 to 240 VAC
Storage Temperature-25 to 70 °C
Relative Humidity10 to 90% non-condensing

Related product manuals