EasyManuals Logo

Cisco Catalyst 3750-E User Manual

Cisco Catalyst 3750-E
1414 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #766 background imageLoading...
Page #766 background image
32-4
Catalyst 3750-E and 3560-E Switch Software Configuration Guide
OL-9775-08
Chapter 32 Configuring System Message Logging
Configuring System Message Logging
This example shows a partial switch system message on a Catalyst 3560-E switch:
00:00:46: %LINK-3-UPDOWN: Interface Port-channel1, changed state to up
00:00:47: %LINK-3-UPDOWN: Interface GigabitEthernet0/1, changed state to up
00:00:47: %LINK-3-UPDOWN: Interface GigabitEthernet0/2, changed state to up
00:00:48: %LINEPROTO-5-UPDOWN: Line protocol on Interface Vlan1, changed state to down
00:00:48: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/1, changed
state to down 2
*Mar 1 18:46:11: %SYS-5-CONFIG_I: Configured from console by vty2 (10.34.195.36)
18:47:02: %SYS-5-CONFIG_I: Configured from console by vty2 (10.34.195.36)
*Mar 1 18:48:50.483 UTC: %SYS-5-CONFIG_I: Configured from console by vty2 (10.34.195.36)
Default System Message Logging Configuration
Disabling Message Logging
Message logging is enabled by default. It must be enabled to send messages to any destination other than
the console. When enabled, log messages are sent to a logging process, which logs messages to
designated locations asynchronously to the processes that generated the messages.
Beginning in privileged EXEC mode, follow these steps to disable message logging. This procedure is
o
ptional.
Ta b l e 32-2 Default System Message Logging Configuration
Feature Default Setting
System message logging to the console Enabled.
Console severity Debugging (and numerically lower levels; see
Table 32-3 on page 32-10).
Logging file configuration No filename specified.
Logging buffer size 4096 bytes.
Logging history size 1 message.
Time stamps Disabled.
Synchronous logging Disabled.
Logging server Disabled.
Syslog server IP address None configured.
Server facility Local7 (see Ta
ble 32-4 on page 32-14).
Server severity Informational (and numerically lower levels; see
Table 32-3 on page 32-10).
Command Purpose
Step 1
configure terminal Enter global configuration mode.
Step 2
no logging console Disable message logging.
Step 3
end Return to privileged EXEC mode.

Table of Contents

Other manuals for Cisco Catalyst 3750-E

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco Catalyst 3750-E and is the answer not in the manual?

Cisco Catalyst 3750-E Specifications

General IconGeneral
SeriesCatalyst 3750-E
Switching Capacity32 Gbps
Stacking Bandwidth32 Gbps
StackWise PlusYes
Layer SupportLayer 3
MAC Address Table Size12, 000 entries
RAM256 MB
Flash Memory64 MB
Memory256 MB DRAM, 64 MB Flash
Operating Temperature32 to 113°F (0 to 45°C)
Ports48 10/100/1000 Ethernet ports
Form FactorRack-mountable
Jumbo Frame SupportYes
Input Voltage100 to 240 VAC
Storage Temperature-25 to 70 °C
Relative Humidity10 to 90% non-condensing

Related product manuals