32-9
Catalyst 3750-E and 3560-E Switch Software Configuration Guide
OL-9775-08
Chapter 32 Configuring System Message Logging
Configuring System Message Logging
To disable sequence numbers, use the no service sequence-numbers global configuration command.
This example shows part of a logging display with sequence numbers enabled:
000019: %SYS-5-CONFIG_I: Configured from console by vty2 (10.34.195.36) (Switch-2)
Defining the Message Severity Level
You can limit messages displayed to the selected device by specifying the severity level of the message,
which are described in Table 32-3.
Beginning in privileged EXEC mode, follow these steps to define the message severity level. This
p
rocedure is optional.
Note Specifying a level causes messages at that level and numerically lower levels to appear at the destination.
To disable logging to the console, use the no
logging console global configuration command. To disable
logging to a terminal other than the console, use the no logging monitor global configuration command.
To disable logging to syslog servers, use the no logging trap global configuration command.
Step 4
show running-config Verify your entries.
Step 5
copy running-config startup-config (Optional) Save your entries in the configuration file.
Command Purpose
Command Purpose
Step 1
configure terminal Enter global configuration mode.
Step 2
logging console level Limit messages logged to the console.
By default, the console receives debugging messages and numerically
lo
wer levels (see Table 32-3 on page 32-10).
Step 3
logging monitor level Limit messages logged to the terminal lines.
By default, the terminal receives debugging messages and numerically
lo
wer levels (see Table 32-3 on page 32-10).
Step 4
logging trap level Limit messages logged to the syslog servers.
By default, syslog servers receive informational messages and
n
umerically lower levels (see Table 32-3 on page 32-10).
For complete syslog server configuration steps, see the
Configuring
UNIX Syslog Servers” section on page 32-12.
Step 5
end Return to privileged EXEC mode.
Step 6
show running-config
or
show logging
Verify your entries.
Step 7
copy running-config startup-config (Optional) Save your entries in the configuration file.

Table of Contents

Other manuals for Cisco Catalyst 3750-E

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco Catalyst 3750-E and is the answer not in the manual?

Cisco Catalyst 3750-E Specifications

General IconGeneral
SeriesCatalyst 3750-E
Switching Capacity32 Gbps
Stacking Bandwidth32 Gbps
StackWise PlusYes
Layer SupportLayer 3
MAC Address Table Size12, 000 entries
RAM256 MB
Flash Memory64 MB
Memory256 MB DRAM, 64 MB Flash
Operating Temperature32 to 113°F (0 to 45°C)
Ports48 10/100/1000 Ethernet ports
Form FactorRack-mountable
Jumbo Frame SupportYes
Input Voltage100 to 240 VAC
Storage Temperature-25 to 70 °C
Relative Humidity10 to 90% non-condensing