99-145912-A C-1
Appendix C
System messages C
This appendix has the following sections:
• Event messages – overview
• List of ADU events
• List of ACU events
C.1 Event messages – overview
The SAILOR 100 GX detects events during
• POST (Power On Self Test) – a self test performed at every power-up.
• PAST (Person Activated Self test) – started in the web interface
• CM (Continuous Monitoring) – automatically performed while the
system is in operation.
When the SAILOR 100 GX detects an event that requires your action, it
issues an event message and the red Fail/Pass LED in the LED panel of the
ACU is lit. As long as an event is active, it is shown in the ACU display, the
Control Panel and the web interface (in HELPDESK > Event list or click the
event icon on the DASHBOARD).
State the Event ID when contacting your service partner.
The event description might contain a number of digits in brackets, e.g.
(00000005). This is supplemental information and used for service and
diagnostics purposes.
Active events and notifications are shown. As soon as the
event is cleared, it is not displayed any longer. It is then moved
to the Notifications section. Notifications are cleared after 24
hours.