Configuration with the web interface
99-145912-A Chapter 6: Configuration 6-23
3. Enter start and stop azimuth value in degrees for the blocking zone.
Values allowed: 0 to 360 degrees. Enter clockwise.
4. Enter the start and stop elevation angle for the blocking zone. If you
enter nothing, there will be no blocking zone. Values allowed: -30 to
90 degrees.
5. Select No TX for zones if you don’t want the system to transmit.
If not selected, the system also transmits when pointing through
areas with blocking objects. The modem will shut off for TX if no
signal is received.
6. Click Apply to save the blocking zones.
Figure 6-16: Blocking zone, example: 315 - 45 degrees
Figure 6-17: Blocking zone, example: 45 - 315 degrees
You must enter 2 different elevation angles to have an
active blocking zone.
$QWHQQD
%ORFNLQJ]RQH
$QWHQQD
%ORFNLQJ]RQH