Section 3: Using Sensors
30
LEMO To attach a LEMO triple BNC adapter, line up the red dot on
the LEMO connector with the red line on the instrument socket and
insert. Remove by firmly gripping the connector and pulling away
from the instrument without twisting.
Warning: Do not remove the LEMO connector by pulling the sensor
cable. This may damage the cable. Always remove by gripping the
end connector.
Sensor Inputs
Input vbBalancer vbBalancer+
BNC 1 (Channel 1)
BNC 2 (Channel 2)
LEMO 1 (Channels 2-4)
LEMO 2 (TACH)
Mounting Sensors
Your choice of sensor mounting will affect the accuracy of balance
jobs and vibration measurements.
Accelerometers are usually mounted using the supplied magnetic
base. However, for permanent installations on balancing stands, they
can be stud mounted as described in Permanent Mounting (page
32). You can also apply these instructions to velocity sensors.
You should mount tachometers according to the manufacturer's
instructions.