INS_CNGE3FE8MS[POE][HO] Rev. 11.7.17 PAGE 106
INSTRUCTION MANUAL CNGE3FE8MS[POE][HO]
TECH SUPPORT: 1.888.678.9427
VLAN Configuration
Each page shows up to 99 entries from the VLAN table, default being 20, selected through the
entries per page” input field. When first visited, the web page will show the first 20 entries from
the beginning of the VLAN Table. The first displayed will be the one with the lowest VLAN ID
found in the VLAN Table.
The “VLAN” input fields allow the user to select the starting point in the VLAN Table.
Object Description
Delete Check to delete the entry. The designated entry will be deleted during the next save.
VLAN ID The VLAN ID of the entry.
MLD Snooping
Enabled
Enable the per-VLAN MLD Snooping. Up to 32 VLANs can be selected for MLD Snooping.
Querier Election Enable to join MLD Querier election in the VLAN. Disable to act as a MLD Non-Querier.
Compatibility Compatibility is maintained by hosts and routers taking appropriate actions depending on the
versions of MLD operating on hosts and routers within a network.
The allowed selection is MLD-Auto, Forced MLDv1, Forced MLDv2, default compatibility value
is MLD-Auto.
PRI Priority of Interface.
It indicates the MLD control frame priority level generated by the system. These values can be
used to prioritize different classes of traffic.
The allowed range is 0 (best effort) to 7 (highest), default interface priority value is 0.
RV Robustness Variable.
The Robustness Variable allows tuning for the expected packet loss on a link. The allowed
range is 1 to 255, default robustness variable value is 2.
QI Query Interval.
The Query Interval is the interval between General Queries sent by the Querier. The allowed
range is 1 to 31744 seconds, default query interval is 125 seconds.
QRI Query Response Interval.
The Maximum Response Delay used to calculate the Maximum Response Code inserted into
the periodic General Queries. The allowed range is 0 to 31744 in tenths of seconds, default
query response interval is 100 in tenths of seconds (10 seconds).
LLQI Last Listener Query Interval.
The Last Listener Query Interval is the Maximum Response Delay used to calculate the
Maximum Response Code inserted into Multicast Address Specific Queries sent in response
to Version 1 Multicast Listener Done messages. It is also the Maximum Response Delay used
to calculate the Maximum Response Code inserted into Multicast Address and Source Specific
Query messages.
The allowed range is 0 to 31744 in tenths of seconds, default last listener query interval is 10 in
tenths of seconds (1 second).