Customizing Set Up 25
Cat. No. 01021161
Setting Screen Display Range Changing the Setting
Power Up
Regen
3 Plus
Hours
or
No
By default if a power loss is for more than three hours, the unit
will regenerate when it regains power. Setting this value to No
disables this function, preventing a regeneration after a power
outage of any length.
Media
Life**
100–
1,000,000
For filters only. This setting is used to trigger the media end of
life message/condition. Requires a flow meter.
Regen
Lockout
0–12
This setting prevents back-to-back regenerations on multi-tank
systems, if necessary. When one unit is done regenerating, the
next regeneration cannot begin until the set amount of time has
passed. Press
or then to specify the duration.
5. The regen setup is complete. The screen displays the advanced setup menu.
Press
to display the home screen.
Cycle Times Setup
1. From the HOME screen, press to view the main menu.
2. The screen displays the main menu. Press to select 5)ADV.
SETUP.
3. The screen displays the advanced setup menu. The menu includes SYSTEM SET-
UP, REGEN SETUP, CYCLE TIMES, and REGENTRIGGER.
4. Press to select 3)CYCLE TIMES.
Cycle Times Settings
Use the same procedure to change the values of other cycle times settings. Press to scroll through the settings, un-
less otherwise instructed. After changing the setting, press
to accept the displayed screen value. The Smart Controller
will display the next system setting from the menu.
Setting Screen Display Range Changing the Setting
Cycle
Times
Defaults or
Custom
When USE DEFAULTS is selected, the program calculates the
cycle times based on hardness and resin volume. When CUS-
TOM is selected, you can set custom cycle times. For commer-
cial applications, Press
or and then to select
CUSTOM and verify the settings.