66 Culligan® Smart Controller (GBE) for Softeners and Filters
66 Cat. No. 01021161
3. From the Accessories menu, press to se-
lect 11)EXT. FILTER.
External Filter Settings
Setting Screen Display Range Changing the Setting
External
Filter
Alarm
Installed,
Not
Installed
Press
or and then to change the setting from
INSTALLED to NOT INSTALLED.
Filter
Capacity
Time
Based
Flow
Based
This alarm setting may be set based on how many gallons
have flowed through the unit (requires meter) or may be set
based on time.
Filter
Capacity
0–100000
Press
or and then to change the filter capacity
setting.
Filter
Capacity
1–999
Press
or and then to increase or decrease filter
capacity.
Reset
Capacity
Yes or No
The screen displays a confirmation query. Press
or
and then
to change the setting from NO to YES.
The screen displays the Accessories menu.
Change
Auxiliary
Filter
Yes or No
When the screen displays “Change Auxiliary Filter,” press
.
The screen displays the main menu.
NOTE Once the auxiliary filter has been replaced, the auxiliary filter alarm must be reset by returning to the
same menu: Main Menu / Accessories.
4. Press to save the settings and return to the home screen.