36 Culligan® Smart Controller (GBE) for Softeners and Filters
36 Cat. No. 01021161
3. From the Accessories menu, press to 5)SBT SENSOR.
4. Press the CHECK MARK button. The screen displays the SBT Sensor settings.
Use the same procedure to change the values of other cycle times setup settings. Press the DOWN ARROW button to
change the setting, unless otherwise instructed. After changing the setting, press the CHECK MARK button to accept the
displayed screen value. The Smart Controller will display the next system setting from the menu.
Setting Screen Display Range Changing the Setting
SBT
Sensor
Installed,
Not
Installed
Press
or and then to change the setting from NOT
INSTALLED to INSTALLED if a salt brine tank probe is installed.
Tank
Diameter
0–150
Press
or and then to increase or decrease the tank
diameter, which is used to estimate the number of days the brine
tank has salt.
Salt
Geometry
Pellet/Cube
Rock/Solar
Special
Block/Brick
Use this setting to select the salt geometry (the shape of the
softening salts). Press
or and then to change the
setting.
5. Press to display the home screen.