3.8 MODULE ERROR
This occurs when the control system detects a trip within a specific module. The module will be identified on the diagnostics
screen as described in Section 2.
Check all cables and connections.
Cycle the power.
If the trip is still present after the above checks have been made, then the module identified may be defective. Refer to
Section 5.
3.9 SYSTEM ERROR
This occurs when the system detects a trip that cannot be attributed to a specific module.
Check all cables and connections.
Cycle the power.
If the trip is still present and the system contains 3rd party Modules:
Disconnect all non-Curtiss-Wright modules and cycle the power.
If this has cleared the trip:
Connect each 3rd party module in turn, cycling the power each time.
If the trip reappears after one of the power cycles then the last module to have been added to the system must be
defective.
If the trip is still present after the above checks have been made, then the Curtiss-Wright control system may be defective.
Refer to Section 5.
3.10 SID DETACHED
The Omni2 has detected that the Specialty Input Device (SID) has become disconnected.
Check all cables and connectors between the Omni2 and the SID.
If the error persists:
Check that the setting of the parameters, 9-Way Detect and 9-Way SID Switch Detect, are appropriate for the SID
that is being used. For example, if the SID has no detect-link, then these parameters should be set to Off.
If the trip is still present after the above checks have been made, then the SID may be defective. Contact your service agent.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Curtiss-Wright R-NET OMNI2 and is the answer not in the manual?

Curtiss-Wright R-NET OMNI2 Specifications

General IconGeneral
Input Voltage Range±10 V
Input Impedance1 MΩ
InterfaceEthernet
Operating Temperature-40°C to +85°C
Resolution16 bits
Power Supply9-36V DC