Curtiss-Wright | PG Drives Technology
SK81935-01
134 | R-net Omni2 Technical Manual | Chapter 8 Diagnostics
3.11 USER SWITCH DETACHED
The Omni2 has detected that the User Switch has become disconnected.
Check all cables and connectors between the Omni2 and the User Switch.
If the trip is still present after the above checks have been made, then the User Switch may be defective. Contact your service
agent.
If it is required to use the Omni2 without a User Switch being connected, then the parameters, Switch Detect and User Switch
Detect, should be set to Off. If a User Switch is not used the responsibility for that decision lies with the healthcare
professional.
WARNING (HP, IN)
Because a disconnected User Switch means there is no emergency-stop function, Curtiss-Wright recommend that Switch
Detect is always set to On. Curtiss-Wright will accept no liability for any losses resulting from any other setting of this
parameter.
3.12 OVER PRESSURE
The Omni2 has detected that the pressure on the Sip and Puff transducer has exceeded its maximum level. Although a trip
screen is not displayed the system log will show the trip and number of occurrences.
Check the user is operating the Sip and Puff device correctly.
If the trip is still present after the above check has been made, then the Omni2 may be defective. Refer to Section 5.
3.13 GONE TO SLEEP
This occurs when the control system has been left inactive for a time greater than the parameter setting of Sleep Timer.
An entry is made in the system log each time this occurs.
3.14 CHARGING
This occurs when the control system detects that a charger is connected to the Neutrik socket on the Input Section. Refer to
section 2.3 for connection details
The Battery charging screen will be displayed during charger connection.
An entry is made in the system log each time this occurs.
If an Off-Board Charger is used:
Disconnect the charger from the Wheelchair.
If the trip is still present after the charger has been disconnected then the Omni2 may be defective. Refer to Section 5.