239
8.3.1.2.2 Cancelling Binding NIC
Cancel port aggregation and allow the bonded NICs to work as independent card.
Step 1 Click or click on the configuration page, and then select
NETWORK > Basic
Network > TCP/IP.
Step 2 Select a bonded NIC.
Step 3 Click OK.
System splits the bonded NIC.
After splitting NIC binding, the first NIC reserves the IP address configured during binding,
while the rest NICs restore default IP addresses.
8.3.1.3 Setting Port Number
Set device port number.
Step 1 Click , or click on the configuration page, and then select
NETWORK > Basic
Network > Port.
Figure 8-24 Port
Step 2 Set parameters.
Log in again after modifying parameters except Max Connection.
Table 8-9 Connection setting parameters description
Parameters
Description
Max Connection
The allowable maximum clients accessing the Device at the same
time, such as web, PCAPP, and Platform. Select a value between 1 and
128. The default value setting is 20.
TCP Port
Set according to the actual requirements. The default value is 37777.
The value ranges from 1025 to 65535.
RTSP Port
Set according to the actual requirements. The default value is 554. The
value ranges from 1 to 65535.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dahua Technology DHI-IVSS7124 and is the answer not in the manual?

Dahua Technology DHI-IVSS7124 Specifications

General IconGeneral
BrandDahua Technology
ModelDHI-IVSS7124
CategoryDVR
LanguageEnglish

Related product manuals